OPER 0.30

OPER 0.35
OPER 0.40

OPER 0.50
|
|
Magnet System
- Type: Permanent magnet, eddy current free, open C type & self-temperature control
- Field Strength: 0.3T, 0.35T, 0.4T, 0.5T
- Field Homogeneity: <2ppm (FWHH)/20cm DSV
- <5ppm (Vrms)/40cm DSV
- Vertical gap distance: 40cm
Gradient System
- Amplifier: COPLEY Co., USA
- Field Strength: single axis 18mT/m, effective 30.6mT/m
- Field Slew rate: single axis 55mT/m/ms, effective 93.5 mT/m/ms
- Field Linearity: 40cm ~40m ~38cm ellipsoid <5%
RF System
- Type of transmitter & receiver: Digital (RI Co., UK)
- Frequency range: DC~22MHz
- Maximum receiver bandwidth: 1.25MHz
- Pre-amplifier: 30dB
- Noise figure: 0.3dB
- RF amplifier: 5KW(ANALOGIC Co., USA)
- RF transmitting coil: panel transmitting coil
- Type of receiving coil: Quadrature coil\Linear coil
Automatic Functions
- Auto pre-scan function
- Auto RF correction
- Auto frequency lock
- Auto gain
- Auto coil identification
- Auto coil tuning
Image Specifications
- Image Types:T1 weighted image, T2 weighted image,
- T2* weighted image, PD weighted image,
- diffusion image, black/white blood image, water suppressed image,
- fat suppressed image
- Field of View: 50mm~400mm
- Acquisition matrix: 64 64~512 512 variable
- Graphics matrix max: 1024 1024
- Spatial resolution: 1mm(headin 24cm FOV)
- 1.5mm(body in 30cm FOV)
- Slice orientation: transverse, sagittal, coronal, free oblique,
- multi-slice & multi-range
- Slice gap:0~20mm
|
Pulse Sequence
- Spin echo (SE)
- Multi-slice & Multi-echo (MSME)
- Fast Spin Echo (FSE)
- Single-shot fast spin echo (SSFSE)
- Multi-shot fast spin echo (MSFSE)
- Inversion recovery( IR)
- Short inversion TI IR (STIR)
- Fluid attenuated IR(FLAIR):T1W,T2W
- Inversion recovery fast spin echo (IRFSE)
- Gradient echo (GRE): 2D/3D
- Steady state process GRE (SSPGRE)
- MRA:TOF2D/3D
- Echo Planar Imaging (EPI)
Special Technique
- Water suppressed technique
- Water image technique
- Fat suppressed technique
- Phase coding gradient chosen technique
- Magnetic transfer technique
- Fluid compensation technique
- Pre-saturation tracking technique
- Oversampling technique
- Maximum density projection technique
- Gating technique (ECG & respirationgating)
Patient Communication
Weight Capacity (couch)
Image Display & Post Processing
- Image post processing: fifter, zoom, cut, text illustration & elimination
- Image analysis: interested area illustration, distance measurement
Computer System
- Main: dual-core processor
- Main frequency:(>=2.4GHz)
- Network controller: 1000Mbps
- Memory: 2GB
- Graphics memory: 128MB
- Hard drive: 160GB
- Removable storage: DVD+RW
- Image restruction: <=0.1s(256 256)
- 21" TFT monitor/1280x1024 resolution
Camera Interface
- Digital (fully DICOM 3.0 compatible)
|